Product

Marine Cables

HIS Cable
TMC's marine cables deal with different characteristics depending on what the cable transports, such as oil, LNG, or automobiles. The closed environment at sea can be dangerous. Therefore, cables used in this environment must be flame retardant, low smoke, and halogen free.

Especially, naval cables that are installed in destroyers and
submarines, not only is flame retardant, halogen free, and low smoke necessary, but waterproofing and light weight are also required as well. With its market leading capability in materials and product
technology, TMC has been providing high-tech based products and has been certified by renowned shipbuilding related class, such as Lloyds of U.K. to prove its reliability and credibility.
  • Products :
    S-Route, HIS Cable
  • Cable types :
    Liquid Transport Ship, Liquefied Natural Gas Ship, Liquefied Petroleum Gas Ship, Freight Transport Ship, Automobile Transport Ship, Bulk Carrier Ship
HIS Cable 사진01 HIS Cable 사진02 HIS Cable 사진03
Marine Cables

HIS Cable

CABLE DESIGNATION
  • 3.6/6kV PXY, PCY, POY, PBY
  • 6/10kV PXY, PCY, POY, PBY
  • 8.7/15kV PXY, PCY, POY, PBY
  • 12/20kV PXY, PCY, POY, PBY
APPLICATION STANDARDS
  • Design guide
    : IEC 60092-350 & IEC 60092-354
  • Insulation material
    : IEC 60092-351, HF EPR
  • Sheath material
    : IEC 60092-359, ST2 or SHF1
  • Flame retardant
    : IEC 60332-1 & IEC 60332-3 Category A
  • Halogen content
    : IEC 60754-1, 0.5% (For Halogen free cable only)
  • Smoke emission
    : IEC 61034, 60% (For Halogen free cable only)
  • Fluorine content
    : IEC 60684-2, 0.1% (For Halogen free cable only)
  • pH and conductivity
    : IEC 60754-2, pH (4.3 ) & Conductivity (10 S/mm )

    (For Halogen free cable only)

  • Cold bend/impact (Option)
    : CSA 22.2 NO. 0.3 (-40 ˚C /-35 ˚C )

    (Same as IEC 60092-350, 8.9)

  • Oil resistant (Option)
    : IEEE 1580 TYPE T , at 70 ˚C x4h

    (For PVC sheath material only)

  • Paint resistant (Option)
    : Maker standard

    (Epoxy, Alkyd paint, at 100 ˚C x168h)

    (For PVC sheath material only)

  • Max. rated conductor temperature
    : 90 ˚C